Solar MPPT Charge Controller

frame

  • Maximum power point tracking (MPPT) phased interleaved switch
  • Battery charging current from 10A to 30A
  • Battery charging with maximum current constant voltage
  • (MCCV) with temperature compensation
  • Solar panel support up to 10,000Wp
  • Peak efficiency 98%
  • Panel input high voltage, lightning , accidental high current panel protection
  • Panel reversal, battery reversal protections
  • Accumulator solar energy meter reading on LCD

Solar Pumping System

frame

  • Maximum Power Point Tracking (MPPT)
  • Variable Frequency drive (VFD)
  • Solar efficiency 98%
  • No battery operation
  • Pure sine wave, 3 phase supply to pump
  • Versatile pump support up to 10 HP
  • Fully automatic running and data storage
  • Complete system protection
  • Dawn to dusk water pumping
CONTROLLER

SOLAR CHARGE CONTROLLER 12V 30A (PWM)


CONTROLLER1

SOLAR CHARGE CONTROLLER 24V 30A (PWM)


CONTROLLER2

SOLAR CHARGE CONTROLLER 60A 24V (PWM)


CONTROLLER3

SOLAR CHARGE CONTROLLER 60A 12V (PWM)


CONTROLLER4

MPPT SOLAR CHARGE CONTROLLER 5120 SM


CONTROLLER5

MPPT SOLAR CHARGE CONTROLLER 2048S+


CONTROLLER6

MPPT SOLAR CHARGE CONTROLLER 1024S+

Solar Cables

cables

  • 4 mm2 thickness -wholesale 55, retail 60 rs per mtr.
  • 6 mm2 thickness -wholesale 75, retail 80 rs per mtr.
  • 10 mm2 thickness -wholesale 120, retail 125 rs per mtr.
  • 16 mm2 thickness -wholesale 155, retail 160 rs per mtr.

Solar Connectors

connectors

Coming Soon

DCDB

dcdb

  • High quality abs enclosure with transparent lid
  • Input positive-dc fuse
  • Premium quality terminal connector
  • Range from 1KW to 50 KW
  • MNRE approved products only

ACDB

acdb

em,mcb,mov,and glands

AJB

ajb

  • ABS ENCLOSURE:ip65
  • Input positive-dc fuse
  • Input negative –t/b
  • Dc switch 63a/250v
  • Output terminal block-earth
  • Dc spd
  • Cable gland for i/p terminal
  • Cable gland for o/p terminal
  • Din rail,hardware etc

Solar Battery

solarbattery

  • Similar to the tubular battery offerings, only difference being their capacity to withstand partial state of discharge (PSOC) operation
  • Deep discharged batteries(upto 80%)
  • Specially designed for rural and high power outage areas.
  • Consistent power output & high back-up.
  • Minimum maintenance.
  • Specifically designed to deliver reliable and consistent power for renewable energy requirements and perform in rural & power deficit areas with minimum maintenance.

Solar Panel Structure

panel-structure

  • 1:2 inch 8mtr gi
  • End Clamp
  • Mid Clamp
  • Fast And Easy Mounting
  • Concrete Block
  • 6000 per kw

1KVA SOLAR INVERTER

Mains Input
Nominal input230V AC, 50 Hz
Input Voltage cut off
Computer mode
165 - 175V AC
Normal mode110 - 125V AC
Input voltage higher cut off250 - 280V AC
Input connection3 pin plug (15A)
Output: Inverter Mode
Output power (VA/Watt)1000
Output frequency (Hz)49 – 51
Output voltage waveformSine wave
Output connection3 pin outlet, 15A
Output: Mains ModeSame as input
Other Specifications
Efficiency85%
LCD indicationStatus of UPS
Audible alarmBattery low, Mode changeover
Battery Voltage24 V
Battery capacity – recommended (AH)300
Dimension300 (W) x 405 (D) x130 (H) mm
Net weight7.5 Kgs
Charging currentConstant current boost &trickle charging

2KVA SOLAR INVERTER

Mains Input
Nominal input230V AC, 50 Hz
Input Voltage cut off
Computer mode
165 – 175V AC
Normal mode110-125V AC
Input voltage higher cut off250-280V AC (configurable)
Input connection3 pin plug ( 15A)
Output: Inverter Mode
Output power (VA/Watt)2000
Output frequency (Hz)49 – 51
Output voltage waveformSine wave
Output connection3 pin outlet, 15A
Output: Mains ModeSame as input
Other Specifications
Efficiency85%
Transfer time15 milliseconds
LCD indicationStatus of UPS
Audible alarmBattery low, Mode changeover
Noise levelLess than 50 dB
Battery Voltage48 V
Battery capacity – recommended (AH)300
Typical Low Voltage Alarm Voltage (V)44.0
Typical shut down battery voltage (V)43.2
Dimension300 (W) x 405 (D) x130 (H) mm
Net weight7.5 Kgs
Charging currentConstant current boost &trickle charging

5KVA SOLAR INVERTER

Mains Input
Nominal input230V AC, 50 Hz
Input Voltage cut off
Computer mode
165 – 175 VDC
Normal mode125-135 VDC
Input voltage higher cut off250-280 V AC
Input connection3 way terminal block
Output: Inverter Mode
Output voltage (VAC)220 +/- 10%
Output power (VA/Watt)5000
Power factor0.8 lag to unity
Output frequency (Hz)49 – 51
Output voltage waveformPure sine wave
Output connection3 way terminal block
Output: Mains ModeSame as input
Other Specifications
Transfer time<3 milliseconds
Efficiency90%
LCD indicationStatus of UPS
Audible alarmBattery low, Over Load, Short Circuit, UPS Mode, Mode changeover
Noise levelLess than 50 dB
Battery Voltage120 VDC
Battery capacity – recommended (AH)300
Typical Low Voltage Alarm Voltage (V)112 V
Typical shut down battery voltage (V)108 V
DimensionDimension : 320 (W) x 525 (D) x 500 (H) mm
Net weight65 Kgs
Charging currentConstant current boost & trickle charging

7.5KVA SOLAR INVERTER

Mains Input
Nominal input230V AC, 50 HZ
Input Voltage cut off
Computer mode
165 – 175 VDC
Normal mode125-135 VDC
Input voltage higher cut off250-280 V AC
Input connection3 way terminal block
Output: Inverter Mode
Output voltage (VAC)220 +/- 10%
Output power (VA/Watt)7500
Power factor0.8 lag to unity
Output frequency (Hz)49 – 51
Output voltage waveformPure sine wave
Output connection3 way terminal block
Output: Mains ModeSame as input
Other Specifications
Transfer time<3 milliseconds
Efficiency90%
LCD indicationStatus of PCU
Audible alarmBattery low, Over Load, Short Circuit, UPS Mode, Mode changeover
Noise levelLess than 50 dB
Battery Voltage144 VDC
Battery capacity – recommended (AH)300
Typical Low Voltage Alarm Voltage (V)134.4 V
Typical shut down battery voltage (V)129.6 V
DimensionDimension : 420 (W) x 689 (D) x 657 (H) mm
Net weight80 Kgs
Charging currentConstant current boost & trickle charging